  Cryopump Indium  
 

 

Cryopump Indium Gasket Kits

Description 99.99% Pure Indium            P/N      Price
Indium Gasket Set, Precut, CT-8 Cryopump           IN-CT8       $50.00
Indium Gasket Set, Precut, CT-8            On-Board* Cryopump         IN-CT8OB       $50.00
Indium Gasket Set, Precut, CT-8F Cryopump          IN-CT8F       $50.00
Indium Gasket Set, Precut, CT-8F            On-Board* Cryopump        IN-CT8FOB     $100.00
Indium Gasket Set, Precut, CT-10 Cryopump

 IN-CT10

    $100.00
Indium Gasket Set, Precut, CT-10          On-Board* Cryopump

  IN-CT10OB

    $100.00
Indium Sheet, 3"x5" x .005"           IN-3x5       $40.00

 

 Indium Gasket Kit For CT-8

IN-CT8

  Indium Gasket                        Location            Size     Qty
                A Goes between the first stage cold station and the 80K Radiation Shield      3.062" Dia.       1
                B Goes between the second stage cold station and the 15K Array      1.875" Dia.       1
                C Goes between the second stage cold station and the diode sensor or HVB sensor        .437" Dia.       1
                D Goes between the 15K Array, and the Top Plate       1.875" Dia.       1
                E Goes between the 80K Radiation Shield brackets and the 80K Condensing Array        .625" Sq.       4

 

Indium Gasket Kit For CT-8 On-Board*

IN-CT8OB

Indium Gasket Location Size Qty
              A Goes between the first stage cold station and the 80K Radiation Shield        3.062" Dia.       1
              B Goes between the 15K Array, and the Top Plate       1.875" Dia.       1
              C Goes between the second stage cold station and the diode sensor        .437" Dia.       1
              D Goes between the second stage cold station and the second stage heater mount       1.875" Dia.       1
              D Goes between the second stage heater mount and the 15K Array       1.875" Dia.       1
              E Goes between the 80K Radiation Shield brackets and the 80K Condensing Array        .625" Sq.       4

 

Indium Gasket Kit For CT-10

IN-CT10

   Indium Gasket                         Location          Size      Qty
               A Goes between the first stage cold station and the 80K Radiation Shield, 2 halves    3.50" X 2.50" Dia.       1
               B Goes between the second stage cold station and the 15K Array         2.250" Dia.       1
               C Goes between the second stage cold station and the diode sensor or HVB sensor         .437" Dia.       1
               D Goes between the 15K Array, and the Top Plate         2.250" Dia.       1
               E Goes between the 80K Radiation Shield brackets and the 80K Condensing Array        1 .000" Sq.       4

 

Indium Gasket Kit For CT-10 On-Board*

IN-CT10OB

Indium Gasket Location Size Qty
               A Goes between the first stage cold station and the 80K Radiation Shield    3.50" X 2.50" Dia       1
               B Goes between the 15K Array, and the Top Plate        2.250" Dia.       1
               C Goes between the second stage cold station and the diode sensor        .437" Dia.       1
               D Goes between the second stage cold station and the second stage heater mount       2.250" Dia.       1
               D Goes between the second stage heater mount and the 15K Array        2.250" Dia.       1
               E Goes between the 80K Radiation Shield brackets and the 80K Condensing Array        1.00" Sq.       4

&

Custom Size Precut Indium Gaskets are available by request.

 gaskets

Indium Indium Gasketsindium gaskets indium gasket se

*Registered trademark of Helix Technology Corp., Brooks Automation


Home Page | About Us | Contact Us |  |  |  | Refurbished Adsorbers | Helium Lines | Links | Cryopump Repair Parts | 15K Array | Manuals |  | Surplus | Exchange Program | Cables